Impact Analysis of Roller System Stability for FourHigh Mill ...
The F3 mill upper work roller vibration acceleration testing timedomain parameters on field is shown in Table can be seen that although axial force is less than 1% of the rolling force, roller axial vibration acceleration amplitude is close to vertical acceleration and lateral acceleration, so the axial force (caused by rollers cross) destruction on the system stability cannot be ignored ...